Steel Bridge Structure
Parameter
Overall length : different sizes
Customer : Ethiopian Construction Works Corporation (ECWC)
All technical specification is by customer requirement




Manufacture And Install Factory Components
Parameter
Over all dimension : Different Sizes
Product name : Sugar processing components
Experience : Welkayt Sugar processing components Project – 3 big sugar factories 12000
Customer : sugar companies
All Components
Juice Treatment and clarification
Juice heating and evaporation
Graining and crystallization
Centrifugal and condensing station
Refinery station and sugar handling and drying
Molasses tanker
Note: All technical specification is by customer requirement


Power Transmission & Distribution Structure
Parameter
Over all dimension : Different Sizes
Transmission Towers : Lattice , square/triangular cross-section.
Distribution Poles : Tubular steel poles, spun concrete pole
Voltage Range : 11 kV – 765 kV (AC) / ±500 kV (DC).
Material
Grade : IS 2062 E250/E350 , ASTM A572 Gr. 50, or EN 10025 S355 (or equivalent international grade).
Erection: Towers erected section by using , cranes, or gin poles
Structural Design
IS 802 (Use of structural steel in transmission line towers).
IEC 60826 (Design criteria of overhead transmission lines).
ASCE 10-15 (Lattice transmission structures).
EN 50341 (Overhead electrical lines)
Traffic Light Pole Structure
Parameter
Over all dimension : Different Sizes
Structure Type
Type : Steel pole (straight, stepped, or swagged) or lattice tower
Mounting : Cantilever arm, mast arm, or overhead gantry
Height : 4–12 m (urban roads), up to 15 m (highways).
Configuration : Single-arm, double-arm, or gantry (spanning )
Structure Type
IS 2062 E250/E350, ASTM A572 Gr. 50, EN 10025 S355.
Erection: Towers erected section by using , cranes, or gin poles
Structural Design
IS 875 (Part 3) / ASCE 7 / Eurocode EN 1991-1-4 (Wind loads).
IS 800 / Eurocode 3 (Steel structures)
Customers
Transport & Road Development Bureau
Construction, and Road Authority
Mekelle City Administration, Tigray Urban Development




Automatic Power Factor Corrector
Parameter
Over all dimension : Different Sizes
Scope : Design, supply, installation, and commissioning To maintain target power factor
Major Components
Capacitors, Switching Devices, Protection Devices, Controller (APFC Relay)Busbars & Enclosure
System Ratings
Rated Voltage
Reactive Power Compensation Range
Target Power Factor
Control Method
Testing & Quality
Routine tests as per IEC
Factory Acceptance Test (FAT)
Site Acceptance Test (SAT) after installation
