Steel Bridge Structure

Parameter

Overall length : different sizes
Customer : Ethiopian Construction Works Corporation (ECWC)
All technical specification is by customer requirement

Manufacture And Install Factory Components

Parameter

Over all dimension : Different Sizes
Product name : Sugar processing components
Experience : Welkayt Sugar processing components Project – 3 big sugar factories 12000
Customer : sugar companies

All Components

Juice Treatment and clarification
Juice heating and evaporation
Graining and crystallization
Centrifugal and condensing station
Refinery station and sugar handling and drying
Molasses tanker
Note: All technical specification is by customer requirement

Power Transmission & Distribution Structure

Parameter

Over all dimension : Different Sizes
Transmission Towers : Lattice , square/triangular cross-section.
Distribution Poles : Tubular steel poles, spun concrete pole
Voltage Range : 11 kV – 765 kV (AC) / ±500 kV (DC).

Material

Grade : IS 2062 E250/E350 , ASTM A572 Gr. 50, or EN 10025 S355 (or equivalent international grade).
Erection: Towers erected section by using , cranes, or gin poles

Structural Design

IS 802 (Use of structural steel in transmission line towers).
IEC 60826 (Design criteria of overhead transmission lines).
ASCE 10-15 (Lattice transmission structures).
EN 50341 (Overhead electrical lines)

Traffic Light Pole Structure

Parameter

Over all dimension : Different Sizes

Structure Type

Type : Steel pole (straight, stepped, or swagged) or lattice tower
Mounting : Cantilever arm, mast arm, or overhead gantry
Height : 4–12 m (urban roads), up to 15 m (highways).
Configuration : Single-arm, double-arm, or gantry (spanning )

Structure Type

IS 2062 E250/E350, ASTM A572 Gr. 50, EN 10025 S355.
Erection: Towers erected section by using , cranes, or gin poles

Structural Design
IS 875 (Part 3) / ASCE 7 / Eurocode EN 1991-1-4 (Wind loads).
IS 800 / Eurocode 3 (Steel structures)

Customers

Transport & Road Development Bureau
Construction, and Road Authority
Mekelle City Administration, Tigray Urban Development

Automatic Power Factor Corrector

Parameter

Over all dimension : Different Sizes
Scope : Design, supply, installation, and commissioning To maintain target power factor

Major Components

Capacitors, Switching Devices, Protection Devices, Controller (APFC Relay)Busbars & Enclosure

System Ratings

Rated Voltage
Reactive Power Compensation Range
Target Power Factor
Control Method

Testing & Quality

Routine tests as per IEC
Factory Acceptance Test (FAT)
Site Acceptance Test (SAT) after installation